Field photos · 5 min read

A winterization is one of the most photographed orders in preservation, and one of the most often sent back. The work is routine. The proof is where it goes wrong: a gauge photo nobody can read, a missing zip tie, a toilet shot from the doorway. This is the shot list we hold every winterization to.

Before you touch anything

  • Every toilet with the lid up, clean and empty, and every sink, tub and shower trap.
  • The water heater, including its pipe connections and, on gas units, the flex line.
  • The heating system: furnace, or the boiler and radiators on a hot water or steam system.
  • The main water shut-off and the meter, close enough to read.

Shutting the water off

  • The main valve closed, with a zip tie on the handle so nobody can open it.
  • If the order calls for it, the meter or union disconnected and capped, shown before and after.
  • On a well: the pressure tank, the breaker off and the line disconnected.

The pressure test

This is the part reviewers check hardest, because it is the only proof the lines are dry. A standard dry winterization is tested at 35 psi for 20 minutes unless the work order says otherwise.

  • The air compressor connected to the system and plugged in, before the test starts.
  • The gauge at the start of the test, in focus, with the needle readable.
  • The gauge again every five minutes until the twenty minutes are up.
  • Air blowing clear at the open faucets.
Loses

One gauge photo at the end of the test.

Wins

Gauge at 0, 5, 10, 15 and 20 minutes, each one readable, all from the same spot.

A single reading proves the gauge worked once. A series proves the system held pressure.

Draining and antifreeze

  • The water heater drain open and draining, and the breaker off on an electric unit.
  • The antifreeze bottle, then antifreeze going into every trap, toilet bowl and tank.
  • Washer drain, dishwasher and hose bibs.
  • On a boiler: the radiator vents open and the boiler being drained.

Stickers and departure

  • A winterization sticker on every fixture and on the main valve, with the sticker readable in the photo.
  • The thermostat setting if the heat must stay on.
  • Every exterior door closed and locked on the way out.

When the test fails

A failed pressure test is not a failed order. Photograph where it leaks, write down what you found, and report it. A leak you document becomes a repair bid. A leak you ignore becomes a burst pipe and a chargeback.

Write the result in your notes every time, for example: dry heat, gas, held 35 psi for 20 minutes, 3 toilets, 4 traps. The processor matches your notes to the photos, so the two should tell the same story.